Maple Professional
Maple Academic
Maple Student Edition
Maple Personal Edition
Maple Player
Maple Player for iPad
MapleSim Professional
MapleSim Academic
Maple T.A. - Testing & Assessment
Maple T.A. MAA Placement Test Suite
Möbius - Online Courseware
Machine Design / Industrial Automation
Aerospace
Vehicle Engineering
Robotics
Power Industries
System Simulation and Analysis
Model development for HIL
Plant Modeling for Control Design
Robotics/Motion Control/Mechatronics
Other Application Areas
Mathematics Education
Engineering Education
High Schools & Two-Year Colleges
Testing & Assessment
Students
Financial Modeling
Operations Research
High Performance Computing
Physics
Live Webinars
Recorded Webinars
Upcoming Events
MaplePrimes
Maplesoft Blog
Maplesoft Membership
Maple Ambassador Program
MapleCloud
Technical Whitepapers
E-Mail Newsletters
Maple Books
Math Matters
Application Center
MapleSim Model Gallery
User Case Studies
Exploring Engineering Fundamentals
Teaching Concepts with Maple
Maplesoft Welcome Center
Teacher Resource Center
Student Help Center
Connections between the ScientificErrorAnalysis and ScientificConstants Packages
Description
Although ScientificErrorAnalysis and ScientificConstants are separate packages, there are many connections between them.
Relationship of ScientificConstants to ScientificErrorAnalysis
The Constant() and Element() objects of ScientificConstants represent quantities with associated uncertainties. The method to access the uncertainties (that is, the ScientificConstants[GetError] command) is available to ScientificErrorAnalysis because it has been added using ScientificErrorAnalysis[AddStructure].
Hence, to ScientificErrorAnalysis, the Constant() and Element() objects of ScientificConstants are quantities-with-error, and can be included in error analysis calculations, for example, with combine/errors.
Furthermore, the derivations of the derived physical constants of ScientificConstants are also available to ScientificErrorAnalysis (because they have been added using ScientificErrorAnalysis[AddStructure]), allowing the derived constants to be treated as quantities-with-error with functional dependence.
ScientificErrorAnalysis has defined a correlation matrix between 18 of the nonderived physical constants of ScientificConstants (using ScientificErrorAnalysis[SetCorrelation]). This reflects the statistical dependence of their uncertainties as determined by the CODATA 1998 Adjustment. See Initial Physical Constants for an overview of the CODATA 1998 Adjustment.
If ScientificErrorAnalysis[Variance] or ScientificErrorAnalysis[Covariance] is called with derived physical constant arguments (for example, from combine/errors or ScientificConstants[GetError]), the usual formula of error analysis involving a first-order expansion is used to calculate the covariance or variance, which uses the correlation matrix. This is essentially the method of extending the covariance matrix for the duration of the calculation.
Relationship of ScientificErrorAnalysis to ScientificConstants
ScientificConstants uses ScientificErrorAnalysis to calculate the errors of derived physical constants (using ScientificErrorAnalysis[Variance]).
See Initial Physical Constants for an overview of the constant derivations, as determined by the CODATA 1998 Adjustment.
GetError Commands
The ScientificConstants[GetError] command accepts only ScientificConstants objects.
However, the ScientificErrorAnalysis[GetError] command accepts any quantity-with-error because the methods used to access them have been made available with ScientificErrorAnalysis[AddStructure]).
Therefore, it is recommended that if short form command calling sequences are used for both packages, with(ScientificErrorAnalysis) be performed after with(ScientificConstants).
Relevance of Systems of Units in ScientificConstants to ScientificErrorAnalysis
Because ScientificErrorAnalysis stores correlation coefficients, it neither has nor requires explicit recognition of systems of units.
Of course, variances and covariances involving physical constants are not scale-free, but these are calculated naturally and correctly by ScientificErrorAnalysis in the implied system of units because central values and errors are obtained from the interface to ScientificConstants.
Unusual cases are possible involving the covariance between the same physical constant in different systems, but expected results are obtained. See Covariance.
See Also
combine/errors, Initial Physical Constants, ScientificConstants, ScientificConstants[Constant], ScientificConstants[Element], ScientificConstants[GetError], ScientificErrorAnalysis, ScientificErrorAnalysis References, ScientificErrorAnalysis/Details, ScientificErrorAnalysis[AddStructure], ScientificErrorAnalysis[Covariance], ScientificErrorAnalysis[GetError], ScientificErrorAnalysis[GetStructure], ScientificErrorAnalysis[GetStructures], ScientificErrorAnalysis[SetCorrelation], ScientificErrorAnalysis[Variance], with